Table of Contents

Enum InputMultiplexer

Namespace
Iot.Device.Ads1115
Assembly
Iot.Device.Ads1115.dll

Configure the Input Multiplexer.

public enum InputMultiplexer

Fields

AIN0 = 4

AIN Positive = AIN0 and AIN Negative = GND Measure the Voltage between AIN0 and GND.

AIN0_AIN1 = 0

AIN Positive = AIN0 and AIN Negative = AIN1 Measure the Voltage between AIN0 and AIN1.

AIN0_AIN3 = 1

AIN Positive = AIN0 and AIN Negative = AIN3 Measure the Voltage between AIN0 and AIN3.

AIN1 = 5

AIN Positive = AIN1 and AIN Negative = GND Measure the Voltage between AIN1 and GND.

AIN1_AIN3 = 2

AIN Positive = AIN1 and AIN Negative = AIN3 Measure the Voltage between AIN1 and AIN3.

AIN2 = 6

AIN Positive = AIN2 and AIN Negative = GND Measure the Voltage between AIN2 and GND.

AIN2_AIN3 = 3

AIN Positive = AIN2 and AIN Negative = AIN3 Measure the Voltage between AIN2 and AIN3.

AIN3 = 7

AIN Positive = AIN3 and AIN Negative = GND Measure the Voltage between AIN3 and GND.